Wireless fire alarms (Ajax EN54)
Wireless fire alarms fit where cabling is disruptive, expensive or not allowed: listed buildings, busy offices, schools in term time and care homes. We install the Ajax EN54 range, designed and commissioned to BS 5839-1:2025, and our new Ajax EN54 systems can include FireFind.
- BAFE SP203-1
- Registered No. 303674
- Modules held
- All four: design to maintenance
- Certification body
- NSI (Fire Silver)
- Designed to
- BS 5839-1:2025
- Google reviews
- 120+ five-star
When wireless makes sense
- Listed and historic buildings: no chasing walls and far fewer fixings
- Occupied premises: installed in hours or days rather than weeks, with little dust or noise
- Care homes and schools: less disruption to residents and pupils
- Extensions and outbuildings: where running cable back to a panel isn’t practical
- Changing layouts: devices can be moved as the building changes
The Ajax EN54 range
Ajax’s EN54 line is a complete wireless fire system: the EN54 Fire Hub control panel, smoke, heat and multi-sensor detectors (some with built-in sounders), sounders and visual alarm devices, manual call points, a range extender and an input/output module for connecting other equipment.
We’re an Ajax installer, and we design every Ajax EN54 system to BS 5839-1:2025 like any other fire alarm, starting with a radio survey of the building. At handover you get a wireless signal report alongside the usual certificates.


Wired or wireless?
Both can be designed to BS 5839-1:2025. The right choice depends on your building, how it’s used and your budget.
| Wired (conventional or addressable) | Wireless (Ajax EN54) | |
|---|---|---|
| Installation | Cable to every device; longer on site | Much less cabling; usually quicker |
| Disruption | Chasing, drilling and access to ceilings | Minimal, which suits occupied and listed buildings |
| Equipment cost | Lower | Higher |
| Labour cost | Higher | Lower |
| Batteries | Standby batteries at the panel only | Batteries in every device, replaced periodically |
| Changes later | New cable runs needed | Devices can be added or moved easily |
Case study: a 54,000 sq ft warehouse
At Fileder Filter Systems’ three-storey warehouse in Maidstone, we installed 138 Ajax EN54 devices without running a single cable, and one range extender covered the whole building despite the metal racking. Ajax Systems featured the project as a customer story.
Built by Nova: FireFind
Every new Ajax EN54 system we install can include FireFind, our own fire location service. When the alarm operates, keyholders get a link to the building’s floor plan showing which detector has operated, and where the fire is spreading as more detectors operate.
It works alongside your panel and alarm monitoring. It doesn’t replace them, or a 999 call.
Wireless fire alarm questions
Are wireless fire alarms reliable?
Yes, when they’re designed and installed properly. Radio devices must meet EN 54-25, which covers signal loss through the building, interference and loss of communication, and each device also meets its own part of EN 54. BS 5839-1:2025 has a dedicated clause on radio-linked systems. We carry out a radio survey before we install, and hand over a wireless signal report at commissioning.
Do the batteries need changing?
Yes, periodically. Ajax states device batteries last up to five years, and up to seven years in the call point. We check battery condition at every service and plan replacements, so you’re never caught out.
Is Ajax EN54 approved to BS 5839-1?
BS 5839-1 is a code of practice for designing, installing and maintaining systems, not a product approval. Ajax EN54 devices are certified to the relevant parts of EN 54, including EN 54-25 for radio, and we design, install and commission the system to BS 5839-1:2025.
Can wireless devices be added to our existing wired system?
Not usually to a different make of panel. The Ajax EN54 range works with its own hub, and its input/output module can pass signals to and from other equipment. We’ll look at your system and tell you what makes sense.
Is a wireless system cheaper?
Equipment usually costs more and installation usually costs less, because there’s far less cabling. Where both would suit your building, we can price both.
Ask about a wireless system
Tell us a little about the building and we’ll call you back within one working day. Prefer to talk? Call 01303 720282.
Or talk to us
Call the office and you’ll speak to someone who knows fire alarms. We’re at Shearway Business Park in Folkestone.
- Phone01303 720282
- WhatsAppMessage us on WhatsApp
- Emailinfo@novasec.co.uk
- OfficeUnit 3 The Regent Centre, Pent Road, Shearway Business Park, Folkestone, Kent CT19 4FL. Directions
- HoursMonday to Friday, 9am to 5pm. 24/7 support line for contracted customers (call and choose option 1).
Wireless fire alarms we’ve installed
A wireless fire alarm for a 54,000 sq ft warehouseAjax EN54 and FireFind for Fileder Filter Systems in Maidstone: 138 devices, no cabling. Featured by Ajax.Read the case study
A wireless fire alarm for Folkestone StorageAjax EN54 through concrete floors and metal storage walls with one range extender, and Fire Beams in three pitched roofsRead the case study